Products
Low Noise Centrifugal Exhaust Fan Box
video
Low Noise Centrifugal Exhaust Fan Box

Low Noise Centrifugal Exhaust Fan Box

The Low Noise Centrifugal Exhaust Fan Box is a newly developed unit that offers dual functionality, high efficiency, and low noise. Users can clearly experience its quiet operation and excellent performance, including strong resistance to high temperatures and reliable ventilation capabilities.
Product Introduction

 

The Low Noise Centrifugal Exhaust Fan Box is an efficient, low-noise centrifugal fan designed for ventilation and smoke extraction. It features a low-noise forward-curved multi-wing centrifugal fan, motor bearings, transmission components, and a sound-attenuating box. With high flow rate, low noise, compact structure, and stable operation, it comes in two types: Type A with external motor for fire smoke exhaust, capable of operating continuously at 300°C for over 60 minutes; Type B with internal motor for general ventilation. Additionally, it can be equipped with different lengths or thicker sound-attenuating boxes to further reduce noise. Suitable for hotels, restaurants, theaters, basements, workshops, offices, and other ventilated spaces.

 

Product Pictures

 

product-800-800
product-800-800

 

Product specification

 

Species:

Centrifugal fan

Use:

Heat dissipation and ventilation

Matching motor power:

0.25-7.5kw

Stress:

Low pressure

Pressurized form:

Single stage

Gas flow direction:

Centrifugal

Property:

Low noise

Fan pressure:

Low pressure fan

Voltage:

380v

Shaft power:

0.25-7.5kw

Weight:

20-80kg

Rotational speed:

1400

 

Product advantage

 

Ultra-Low Noise Design

The Low Noise Centrifugal Exhaust Fan Box utilizes advanced aerodynamic design and precision motor balancing technology to ensure extremely low noise levels during operation. With noise controlled at ≤45dB(A), it reduces average noise by about 20% compared to similar products on the market. This significant advantage stems from its unique blade shape and optimized airflow channel design, effectively minimizing turbulence and vibration for efficient, quiet exhaust.

 

High-Temperature Resistance

The Type A external motor design is specifically for fire smoke extraction, capable of continuous operation at 300°C for over 60 minutes, far exceeding standard product capabilities. This exceptional heat resistance results from special high-temperature materials and an elaborately designed cooling system, ensuring stable performance even under extreme conditions, thus providing strong support for fire safety.

 

Wide Application

Due to its outstanding performance, the Low Noise Centrifugal Exhaust Fan Box is widely used in hotels, restaurants, theaters, basements, workshops, and office buildings, meeting various ventilation needs across different environments.

 

Longevity and Reliability

Using high-quality bearings and transmission components, along with precision-machined impellers, ensures long-term stable operation. The compact and sealed structure also reduces maintenance needs, extending service life. Tests show the product's Mean Time Between Failures (MTBF) exceeds 50,000 hours, significantly higher than the industry average.

 

Intelligent Temperature Control

The built-in intelligent temperature control system adjusts fan speed based on ambient temperature, achieving on-demand exhaust to avoid unnecessary energy consumption. The fan slows down automatically at lower temperatures, reducing noise and energy use; it speeds up when temperatures rise, ensuring comfort. This smart adjustment mechanism saves 20%-30% energy compared to traditional constant-speed fans, making it both eco-friendly and economical.

 

Easy Installation and Maintenance

The product is designed with user convenience in mind, featuring a modular structure that allows for quick installation and disassembly without complex tools, saving time and cost. Its reasonable internal structure facilitates easy cleaning and maintenance, preventing performance degradation due to dust accumulation and extending overall lifespan.

 

Product Usage Notes

 

Installation and Commissioning

When installing the Low Noise Centrifugal Exhaust Fan Box, select a solid, stable base to ensure steady operation. Avoid locations with frequent vibrations or external impacts to reduce performance impact and potential damage risks. During commissioning, follow the manufacturer's manual for correct electrical connections and check all fasteners are securely tightened. Before initial startup, conduct a no-load trial run to observe smooth operation and check for abnormal noise or vibrations; proceed to regular use only if everything is satisfactory.

 

Routine Maintenance and Cleaning

Regular maintenance of the Low Noise Centrifugal Exhaust Fan Box is key to long-term efficiency. Monthly checks for dust buildup inside and outside the fan are essential to prevent heat dissipation issues and increased load. For critical components like the impeller, professional cleaning and maintenance every six months are recommended to remove accumulated dirt and debris, ensuring airflow remains unobstructed. Additionally, inspect bearing lubrication and add oil as necessary to extend lifespan and reduce energy consumption.

 

Temperature and Humidity Monitoring

Despite the device's high-temperature resistance, prolonged operation in extreme heat can accelerate material aging. Install temperature sensors for real-time monitoring to ensure operating temperatures do not exceed specified limits. Although designed with moisture resistance, in high humidity environments, maintain good ventilation to prevent condensation from damaging motor and electrical components.

 

Safe Operation and Emergency Stop

Operators should be trained in the Low Noise Centrifugal Exhaust Fan Box's procedures and safety standards. Never attempt to open the casing or touch moving parts during operation to prevent accidents. In emergencies such as fire or other safety concerns, immediately press the emergency stop button to cut power and follow emergency protocols.

 

Regular Inspections and Record-Keeping

Maintain an operation log recording each maintenance, inspection, and fault resolution event, including dates, actions taken, and outcomes. This aids in tracking the device's condition and provides a reference for future maintenance. Periodically invite professionals for comprehensive checks, especially evaluating the electrical and control systems' safety performance, to keep the equipment in optimal working order.nce metrics, and alerts.

Hot Tags: Low Noise Centrifugal Exhaust Fan Box, China Low Noise Centrifugal Exhaust Fan Box manufacturers, suppliers, factory, hdg steel water tank, hdg steel sectional water tank, industrial dampers, roof mounted extractor fans, roof mounted axial fans, axial flow fans

Send Inquiry